精彩推荐:青光眼 白内障 近视 远视 散光 斜视弱视 角膜溃疡 角膜炎 沙眼 眼外伤 更多疾病
大众频道
专业频道
时尚频道
互动频道
疾 病 | 保 健 | 爱眼动态 | 名医名院
知 识 | 美 食 | 自检自测 | 爱眼纪事
资 讯 | 临 床 | 学 术 | 文 献
图 谱 | 医 患 | 继 教 | 家 园
五官之美 | 整 形 | 美 容
眼镜一族 | 妆 容 | 图 库
眼科在线 | 预留位置
眼科知道 | 在线咨询
  当前位置:当前位置: 中华眼科在线 → 医学频道 → 文献 → 正文 切换到繁體中文 用户登录 新用户注册
Clinical research of intraoperative imageguidance in endoscopic nasocular operation

http://www.cnophol.com 2010-10-21 9:37:45 中华眼科在线

  【摘要】 AIM: To evaluate the availability and our experience of intraoperative imageguidance in endoscopic nasocular operation.METHODS: Seven cases of endoscopic nasal surgery with intraoperative imageguidance were retropectively reviewed, including 3 cases of optic nerve injury;3 cases of foreign object of optic behind the eyeball;1 case of retrobulbar tumor(angeioma). RESULTS: The preoperative preparatory time would take 15 minutes, including coordination, head holder localization, conventional instrument registration.In our cases, the localization accuracy between 3D image landmarks of navigation system and actual anatomical landmarks was less than 1.3mm.The optic nerve and other anatomical points could be orientated accurately in intraoperative procedures. No complication occurred.CONCLUSION: Nasal endoscope combined with imageguidance systems provides accurate anatomical localization of anterior skull base with enlarged operation field.It is possible for surgeons to observe important anatomical structures during endoscopic surgery. It could increase the effectiveness and decrease surgical complications,especially in complicated cases.

  【关键词】 operation on orbit; imageguidance systems; nasal endoscope

  INTRODUCTION

  Because the orbital complex, narrow space, a number of vital organs,so anatomical localization is very important for orbital surgery. Recently,technology for computerassisted surgery was introduced and popularized to improve the overall safety of orbital surgery.This technology allows a direct comparison of intraoperative anatomy with preoperative image information.In this study,a Medtronic, Inc. navigation System for navigation was used during transnasal endoscopic surgeries.

  MATERIALS AND METHODS

  Materials Since August 2008 to December 2009, 7 cases of endoscopic nasal surgery with intraoperative imageguidance were retropectively reviewed,including 3 cases of optic nerve injury;3 cases of foreign object of optic behind the eyeball;1 case of retrobulbar tumor(angeioma). Six males, 1 female, aged 23 to 61 years old, mean age was 45 years old.

  Methods

  Equipment Imageguided system: Medtronic, Inc.; Nasal endoscope: STOZE Inc., Germany; Power system operation: Medtronic XPS3000, Inc.

  Preparing for surgery A highresolution CT spiral scan with serial 1mm thick slices on a horizontal plane was obtained 1 or 2 days before surgery. The image data was transferred to a computer workstation via an optical disk to generate 3D data, from which nine to eleven reference markers were selected for calibration before the surgical procedure.

  At the beginning of each case, a special headset was placed on the patients head, which permitted attachment of a reference flame with lightemitting diodes for optical tracking.

  The navigation functions were activated immediately after the position of the head was determined. The position of the tip of the inhaler was displayed on the workstations screen indicating the location of the target and its adjacent normal structures, confirming the proposed operative field. In all cases, transnasal endoscopic surgery was performed as done previously.

  RESULTS

  Seven cases were successfully performed surgery without complications. Imaging signs and physical anatomical landmark error≤1.5mm. Optic nerve injury in 3 patients, 2 patients with preoperative visual acuity:no light perception and postoperative visual acuity: light perception. One patient with preoperative visual acuity: 0.1 and postoperative visual acuity: 0.5.Three cases of foreign body in orbit: foreign body was successfully removed no significant changes in visual acuity. One case of tumor resection, prognosis is good.

  DISCUSSION

  Because of the complexity of eyeball, orbit and sinuses, eye trauma often appeared with head trauma. Orbital surgery through nasal cavity has many advantages: more efficient, less damage and faster recovery. Application and development of nasal endoscopy promoted the rapid development of orbital surgery[1,2].

  Because the optic nerve is very delicate, and endoscopic surgery is twodimensional image, so image guidance for surgery is very important.

  In this study we used Medtronic Inc. Stealth Station TM system. Imageguided system is to use electromagnetic or infrared signals to determine the precise location in surgery. System uses special computer software, the CT of MRI images of patients before surgery reconstruction, and through electromagnetic induction position on the operation instruments for precise positioning. Doctors operated under the guidance of threedimensional images.

  It is important to calibrate before surgery which has an effect on the accuracy of the navigation system. Medtronic Inc Stealth Station TM system demanded a one to one match of reference marks and points in the threedimensional reconstruction image. In all cases of present study, the average time for preparation is 15 minutes.

  Because the optic nerve in optic foramen is limited, and prone to fracture, optic nerve injury is a kind of so common traumatic eye disease[3]. Current traumatic optic neuropathy treatment is still much controversy, but most scholars believe that surgical treatment can improve the efficiency in a clear imaging diagnosis of optic canal fracture, cavity deformation, hematoma compression or early highdose hormone treatment fails.

  Li and Xu[4] found that surgical treatment of traumatic optic neuropathy is important. Transnasal endoscopic optic canal decompression is commonly used in clinical surgery. In recent years, a lot of successful cases at home and abroad have been reported, with fewer traumas, clear vision and less scar[5,6].

  Imageguided system further reduces surgical risk, increase the success rate. Optic nerve trauma are usually associated with compound fractures, loss of normal anatomic marks[7], endoscopic surgery can not accurately determine the local anatomy. Imageguided system can help doctors determine the exact anatomical location, provide accurate threedimensional images. It reduces serious complications, improve surgical accuracy and safety.

  Patients with optic nerve injury accept VEP examination to evaluate visual function and to judge results of operations, some scholars have reported that accuracy was 90%[8]. But VEP is not the criteria to decide whether surgery, even if it results very poor, we believe that should not give up easily. When doctors found fractures, fracture fragments on the optic nerve compression or disc edema, the patient should undergo surgery as soon as possible. Accurate identification of the optic canal is the key to successful operation[9]. After surgery, although visual acuity may be better, but optic nerve atrophy is still possible.

  Orbital foreign body can lead to a variety of dysfunction. It can affect eye movement, diplopia occur and affect the optic nerve blood supply, leading to optic atrophy[3]. Because the orbital space narrow, and the orbital tissue loose, so doctors are easy to slip foreign body, likely to cause tissue damage. With systems help, doctors can avoid the optic nerve and other vital organs, operate safely and quickly.

  There are some problems associated with the clinic application of the navigation system: Preoperative image examination can not reflect changes in the operation completely; A loose headset can distort the correspondence of one to one matching of reference points and dislocate the structure during surgery; The navigation system required more expenses for instruments and increased the cost of an inpatient. Therefore, doctors need to evaluate comprehensively, select treatment options, in order to achieve better clinical results.

  【参考文献】

  1 Yang ZQ. The development of rhinoneurosurgery and rhinoeyesurgery. Chin J Otorhinolaryngol 1999;34(3):273275

  2 Xv G, Li Y. Jinan University Press. Endoscopic sinus surgery 1994:120122

  3 Li FM, Eye Book. Peoples Medical Publishing House 1996:34413442

  4 Li Y, Xu G. Traumatic optic neuropathy: Importance and result of surgical treatment. Chin J Otorhinolaryngol 2002;37(4):206209

  5 Kountakis SE, Maillard AA, ElHarazi SM, Longhini L, Urso RG. Endoscopic optic nerve decompression for traumatic blindness. Otolaryngol

  Head Neck Surg 2000;123 (1 Pt 1):3437

  6 Luxenberger W, Stammberger H, Jebeles JA, Walch C. Endoscopic optic nerve decompression: the Graz experience. Laryngoscipe 1998;108(6):873882

  7 Ge WT, Zhou B, Han DM. Evaluation of imaging navigation system during endoscopic sinus surgery. Chin Arch Otolaryngol Head Neck Surg 2006;13(8):565569

  8 Wang ZQ, Ma ZZ, Jiang L. The clinical value of Visual Evokecl Potential in traumatic optic neuropathy. Chinese Ophthalmic Reseach 2002;20(3):261263

  9 Sun Y, Li N, Yang SK. Otorhinolaryngology Head and Neck Surgery Techniques. Beijing Science Press 2004:144149

(来源:互联网)(责编:xhhdm)

发表评论】【加入收藏】【告诉好友】【打印此文】【关闭窗口
  • 下一条信息: 没有了
  • 更多关于(operation on orbit,imageguidance systems,nasal endoscope)的信息
    没有相关信息
      热门图文

    眼部保养分早晚 皱纹迟

    甜而不腻的温柔眼妆

    中国面孔诠释本季复苏

    长假见家长MM的必修妆
      健康新看点
      健康多视点
    ad推广
      图话健康
    点击申请点击申请点击申请点击申请点击申请
    中国眼镜网新浪福建健康21世纪药店网千龙求医查疾病114个性导航眼科时讯整形美容英智眼科浙江眼科网中国眼网
    久久眼科网华夏健康网阿里医药眼科网首席医学网寻医问药全球医院网保健医生在线眼科中华临床医师杂志平安健康网卫生法制网

    Copyright © 2007 中华眼科在线 网站备案序列号: 京ICP备08009675号
    本网站由五景药业主办 北京金鼎盛世医学传媒机构负责运营 国家医学教育发展中心提供学术支持
    服务电话:010-63330565 服务邮箱: [email protected]