A clinical study of the wavefront aberrration and contrast sensitivity after Tecnis MF and Array intraocular lens implantation
郭鑫
哈尔滨医科大学附属第一医院眼科医院 150001
Objective To investigate the wavefront aberration and contrast sensitivity after implantation of Tecnis MF and Array intraocular lens(IOL)in patients’eyes with cataract.
Method: IOL implantations were performed in 96(108 eyes)cataract patients.Among which 40 patients(52 eyes)randomly selected ZM900 group,and 56 patients(56 eyes)selected as SA40N group.Aberration and contrast sensitivity were examined at 1 month and 3 month postoperatively,with Allegretto Wave Analyzer and ZM-800 Contrast Sensitivity.
Results:The SA40N group showed significantly higher spherical aberration(p<0.05),C7/C8 aberration(p<0.05)and RMSh(p<0.05)than the ZM900 group at 1 month and 3 month postoperatively.Compare to SA40N,ZM900 group better in contrast sensitivity after 1 month and better in 1.8c/d、3c/d only after 3 month(p<0.05).
Conclusion:ZM900 intraocular lens manifested preferably better capability to decline aberration and raise contrast sensitivity.Therefore,the ZM900 is becoming the tendency of future in choice of intraocular lens.
|